Embed Size px x x x x Energy saving with minimized startup. Startup time of the system has been cr,it short with an op-timized flow rate of circulating solution responsive to thestartup operation quickly. This reduce fuel consumption. Reducing dilution time at the time of operatinginterruption.

Author:Bralrajas Mikinos
Country:Rwanda
Language:English (Spanish)
Genre:Medical
Published (Last):13 August 2015
Pages:89
PDF File Size:9.57 Mb
ePub File Size:3.6 Mb
ISBN:984-3-69155-722-6
Downloads:89707
Price:Free* [*Free Regsitration Required]
Uploader:Daizahn



Embed Size px x x x x Energy saving with minimized startup. Startup time of the system has been cr,it short with an op-timized flow rate of circulating solution responsive to thestartup operation quickly. This reduce fuel consumption. Reducing dilution time at the time of operatinginterruption. By checking the operating condit ion at shut down, minimumdilut ing t ime is determined automatical ly.

Interlocking circuits of auxiliary devices areequipped as a standard. Prevention function for unusual shut down onfailure are equipped. With confinuous monitoring operating conditions by sensorsequipped in the unit, stoppage of the system on failures orfault is minimized in controlling system before the systemgoes to failures..

Dew-point control of the high temperature generator.. Solution temperature control of the high temperature. Pre-alarm system ensure preventive mainte-nance. Fuel control valve indicator.

Combustion timeOperating time of the solutionpump. Abnormal in level control in high tem-water. Perature generator. For a power-failure within the minutes, the unit may startautomatically after the power is recovered.

The unit willshut down with alarm if the power failure lasts more thanten minutes. Operating condition is displayed on the paneldigitally. Temperature in the high temperature generator. Measurement in temperature.. Temperature of the exhaust gas.. Temperature of the evaporating.

Dew point temp. Inlet or Outlet temperature in the cooling water. In an application of inverter control of solution puffiF, saving energy has beenrealized in the whole range from partial loads to rated loads of cooling mode.

Installation costs may be reduced at no control of cooling water temperature andfurther saving in energy consumptiong as operation is feasible as 15'C at theinlet of cooling water. Note 1 The combustion rates shown herein. Series LCooling operation per annual :4 , hou rs o r l ess. Co ld and Ho t Su r face. Refrigerant evaporates in an evaporator and cools down chilled water.

The evaporated refrigerant is absorbed into the solution in the absorber. The solutionabsorbed the refrigerant become weak and sends to the high and low temperature generator respectively through the heat-excangers pumped up by the solutionpump.

The weak solution turns to a concentrated strong solution after heating by the burner in the high temperature generator. The solution becomes mediumstrong solution in the low temperature generator heated by refrigerant steam generated in the high temperature generator.

The strong solution in the high andmedium strong solution in the low temperature are mixed together and back to absorber through the both solution heat-exchangers, in which absorbs therefrigerant evaporated from the evaporator. The generated refrigerant in the low temperature generator move to the condenser and condensed by the cooling water. Condensed refrigerant back to evaporator. View Download 33 Category Documents. Solution temperature control of the high temperature generator.

Temperature rising in the exhaust gas. Rising in the internal pressure. Replacement timing of the burner part. Fault in thermo-sensors. Rising in LTD of cooling water.

Overload in the purge pump. Replacement timing for respectiveoarts. The x mark indicates that only counting is made without displaying any pre-alarm. RCD senbs fb a newly desffiedcompact and hlgh Pertormance,and desffied considering hetter 4. Using a newly developed microprocessor, high performance is realized in operating.

Direct Fired Absorption Chiller-Heater olequipped with latest microprocess orenvironment, In an application of inverter control of solution puffiF, saving energy has beenrealized in the whole range from partial loads to rated loads of cooling mode. Despiece de Bombas Ebara Documents. Ebara Pumps Catalogue Documents.

Ebara 54 Op4 Series Documents. Rcd presentation Documents. RCD Mallorca Sports. Rcd Hipokalemia Documents.

W3SCHOOLS C SHARP TUTORIAL PDF

Absorption and centrifugal water chillers EBARA

Ebara provided seven direct-fired chillers for this commercial center of thousand square to meet summer cooling and winter heating demands. Using coking waste heat for heating and refrigeration, the company adopts double conditions absorption chiller unit. All these kinds of water have low temperature and large amount of residual heat. Heat pump technology are always used for recovering these residual heat source. It is widely used in comfortable air conditioning and the process cooling application. There is a higher requirement for absorption heat pump to adopt waste heat recovery technology. Reliable docking with generator set and ensuring generator set operation safety require application experience of reliable protecting system and heat pump unit, so waste heat recovery transformation is always for small generator set, few for large ones.